Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 14.251
Filtrar
1.
Sci Rep ; 14(1): 8011, 2024 04 05.
Artigo em Inglês | MEDLINE | ID: mdl-38580670

RESUMO

We aimed to retrospectively review outcomes in patients with high-risk prostate cancer and a Gleason score ≤ 6 following modern radiotherapy. We analyzed the outcomes of 1374 patients who had undergone modern radiotherapy, comprising a high-risk low grade [HRLG] group (Gleason score ≤ 6; n = 94) and a high-risk high grade [HRHG] group (Gleason score ≥ 7, n = 1125). We included 955 patients who received brachytherapy with or without external beam radio-therapy (EBRT) and 264 who received modern EBRT (intensity-modulated radiotherapy [IMRT] or stereotactic body radiotherapy [SBRT]). At a median follow-up of 60 (2-177) months, actuarial 5-year biochemical failure-free survival rates were 97.8 and 91.8% (p = 0.017), respectively. The frequency of clinical failure in the HRLG group was less than that in the HRHG group (0% vs 5.4%, p = 0.012). The HRLG group had a better 5-year distant metastasis-free survival than the HRHG group (100% vs 96.0%, p = 0.035). As the HRLG group exhibited no clinical failure and better outcomes than the HRHG group, the HRLG group might potentially be classified as a lower-risk group.


Assuntos
Braquiterapia , Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Gradação de Tumores , Estudos Retrospectivos , Neoplasias da Próstata/patologia , Radioterapia de Intensidade Modulada/efeitos adversos , Dosagem Radioterapêutica , Resultado do Tratamento , Antígeno Prostático Específico
2.
Radiat Oncol ; 19(1): 45, 2024 Apr 08.
Artigo em Inglês | MEDLINE | ID: mdl-38589961

RESUMO

BACKGROUND: Current automated planning solutions are calibrated using trial and error or machine learning on historical datasets. Neither method allows for the intuitive exploration of differing trade-off options during calibration, which may aid in ensuring automated solutions align with clinical preference. Pareto navigation provides this functionality and offers a potential calibration alternative. The purpose of this study was to validate an automated radiotherapy planning solution with a novel multi-dimensional Pareto navigation calibration interface across two external institutions for prostate cancer. METHODS: The implemented 'Pareto Guided Automated Planning' (PGAP) methodology was developed in RayStation using scripting and consisted of a Pareto navigation calibration interface built upon a 'Protocol Based Automatic Iterative Optimisation' planning framework. 30 previous patients were randomly selected by each institution (IA and IB), 10 for calibration and 20 for validation. Utilising the Pareto navigation interface automated protocols were calibrated to the institutions' clinical preferences. A single automated plan (VMATAuto) was generated for each validation patient with plan quality compared against the previously treated clinical plan (VMATClinical) both quantitatively, using a range of DVH metrics, and qualitatively through blind review at the external institution. RESULTS: PGAP led to marked improvements across the majority of rectal dose metrics, with Dmean reduced by 3.7 Gy and 1.8 Gy for IA and IB respectively (p < 0.001). For bladder, results were mixed with low and intermediate dose metrics reduced for IB but increased for IA. Differences, whilst statistically significant (p < 0.05) were small and not considered clinically relevant. The reduction in rectum dose was not at the expense of PTV coverage (D98% was generally improved with VMATAuto), but was somewhat detrimental to PTV conformality. The prioritisation of rectum over conformality was however aligned with preferences expressed during calibration and was a key driver in both institutions demonstrating a clear preference towards VMATAuto, with 31/40 considered superior to VMATClinical upon blind review. CONCLUSIONS: PGAP enabled intuitive adaptation of automated protocols to an institution's planning aims and yielded plans more congruent with the institution's clinical preference than the locally produced manual clinical plans.


Assuntos
Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Masculino , Humanos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Bexiga Urinária , Neoplasias da Próstata/radioterapia , Órgãos em Risco
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(2): 150-155, 2024 Mar 30.
Artigo em Chinês | MEDLINE | ID: mdl-38605613

RESUMO

Objective: A quality control (QC) system based on the electronic portal imaging device (EPID) system was used to realize the Multi-Leaf Collimator (MLC) position verification and dose verification functions on Primus and VenusX accelerators. Methods: The MLC positions were calculated by the maximum gradient method of gray values to evaluate the deviation. The dose of images acquired by EPID were reconstructed using the algorithm combining dose calibration and dose calculation. The dose data obtained by EPID and two-dimensional matrix (MapCheck/PTW) were compared with the dose calculated by Pinnacle/TiGRT TPS for γ passing rate analysis. Results: The position error of VenusX MLC was less than 1 mm. The position error of Primus MLC was significantly reduced after being recalibrated under the instructions of EPID. For the dose reconstructed by EPID, the average γ passing rates of Primus were 98.86% and 91.39% under the criteria of 3%/3 mm, 10% threshold and 2%/2 mm, 10% threshold, respectively. The average γ passing rates of VenusX were 98.49% and 91.11%, respectively. Conclusion: The EPID-based accelerator quality control system can improve the efficiency of accelerator quality control and reduce the workload of physicists.


Assuntos
Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Algoritmos , Calibragem , Eletrônica , Radioterapia de Intensidade Modulada/métodos , Radiometria/métodos
4.
BMC Health Serv Res ; 24(1): 417, 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38570764

RESUMO

BACKGROUND: Adjuvant radiotherapy represents a key component in curative-intent treatment for early-stage breast cancer patients. In recent years, two accelerated partial breast irradiation (APBI) techniques are preferred for this population in our organization: electron-based Intraoperative radiation therapy (IORT) and Linac-based External Beam Radiotherapy, particularly Intensity-modulated radiation therapy (IMRT). Recently published long-term follow-up data evaluating these technologies have motivated a health technology reassessment of IORT compared to IMRT. METHODS: We developed a Markov model to simulate health-state transitions from a cohort of women with early-stage breast cancer, after lumpectomy and adjuvant APBI using either IORT or IMRT techniques. The cost-effectiveness from a private health provider perspective was assessed from a disinvestment point of view, using life-years (LYs) and recurrence-free life-years (RFLYs) as measure of benefits, along with their respective quality adjustments. Expected costs and benefits, and the incremental cost-effectiveness ratio (ICER) were reported. Finally, a sensitivity and scenario analyses were performed to evaluate the cost-effectiveness using lower IORT local recurrence and metastasis rates in IORT patients, and if equipment maintenance costs are removed. RESULTS: IORT technology was dominated by IMRT in all cases (i.e., fewer benefits with greater costs). Despite small differences were found regarding benefits, especially for LYs, costs were considerably higher for IORT. For sensitivity analyses with lower recurrence and metastasis rates for IORT, and scenario analyses without equipment maintenance costs, IORT was still dominated by IMRT. CONCLUSIONS: For this cohort of patients, IMRT was, at least, non-inferior to IORT in terms of expected benefits, with considerably lower costs. As a result, IORT disinvestment should be considered, favoring the use of IMRT in these patients.


Assuntos
Neoplasias da Mama , Radioterapia de Intensidade Modulada , Humanos , Feminino , Neoplasias da Mama/radioterapia , Neoplasias da Mama/cirurgia , Neoplasias da Mama/patologia , Análise Custo-Benefício , Cuidados Intraoperatórios/métodos , Radioterapia Adjuvante , Mastectomia Segmentar/métodos
7.
Sci Rep ; 14(1): 8436, 2024 04 10.
Artigo em Inglês | MEDLINE | ID: mdl-38600141

RESUMO

The purpose of this study was to establish an integrated predictive model that combines clinical features, DVH, radiomics, and dosiomics features to predict RIHT in patients receiving tomotherapy for nasopharyngeal carcinoma. Data from 219 patients with nasopharyngeal carcinoma were randomly divided into a training cohort (n = 175) and a test cohort (n = 44) in an 8:2 ratio. RIHT is defined as serum thyroid-stimulating hormone (TSH) greater than 5.6 µU/mL, with or without a decrease in free thyroxine (FT4). Clinical features, 27 DVH features, 107 radiomics features and 107 dosiomics features were extracted for each case and included in the model construction. The least absolute shrinkage and selection operator (LASSO) regression method was used to select the most relevant features. The eXtreme Gradient Boosting (XGBoost) was then employed to train separate models using the selected features from clinical, DVH, radiomics and dosiomics data. Finally, a combined model incorporating all features was developed. The models were evaluated using receiver operating characteristic (ROC) curves and decision curve analysis. In the test cohort, the area under the receiver operating characteristic curve (AUC) for the clinical, DVH, radiomics, dosiomics and combined models were 0.798 (95% confidence interval [CI], 0.656-0.941), 0.673 (0.512-0.834), 0.714 (0.555-0.873), 0.698 (0.530-0.848) and 0.842 (0.724-0.960), respectively. The combined model exhibited higher AUC values compared to other models. The decision curve analysis demonstrated that the combined model had superior clinical utility within the threshold probability range of 1% to 79% when compared to the other models. This study has successfully developed a predictive model that combines multiple features. The performance of the combined model is superior to that of single-feature models, allowing for early prediction of RIHT in patients with nasopharyngeal carcinoma after tomotherapy.


Assuntos
Hipotireoidismo , Neoplasias Nasofaríngeas , Radioterapia de Intensidade Modulada , Humanos , Carcinoma Nasofaríngeo/radioterapia , Radioterapia de Intensidade Modulada/efeitos adversos , Aprendizado de Máquina , Neoplasias Nasofaríngeas/radioterapia , Estudos Retrospectivos
8.
Radiat Oncol ; 19(1): 48, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622628

RESUMO

BACKGROUND: Tumor regression and organ movements indicate that a large margin is used to ensure target volume coverage during radiotherapy. This study aimed to quantify inter-fractional movements of the uterus and cervix in patients with cervical cancer undergoing radiotherapy and to evaluate the clinical target volume (CTV) coverage. METHODS: This study analyzed 303 iterative cone beam computed tomography (iCBCT) scans from 15 cervical cancer patients undergoing external beam radiotherapy. CTVs of the uterus (CTV-U) and cervix (CTV-C) contours were delineated based on each iCBCT image. CTV-U encompassed the uterus, while CTV-C included the cervix, vagina, and adjacent parametrial regions. Compared with the planning CTV, the movement of CTV-U and CTV-C in the anterior-posterior, superior-inferior, and lateral directions between iCBCT scans was measured. Uniform expansions were applied to the planning CTV to assess target coverage. RESULTS: The motion (mean ± standard deviation) in the CTV-U position was 8.3 ± 4.1 mm in the left, 9.8 ± 4.4 mm in the right, 12.6 ± 4.0 mm in the anterior, 8.8 ± 5.1 mm in the posterior, 5.7 ± 5.4 mm in the superior, and 3.0 ± 3.2 mm in the inferior direction. The mean CTV-C displacement was 7.3 ± 3.2 mm in the left, 8.6 ± 3.8 mm in the right, 9.0 ± 6.1 mm in the anterior, 8.4 ± 3.6 mm in the posterior, 5.0 ± 5.0 mm in the superior, and 3.0 ± 2.5 mm in the inferior direction. Compared with the other tumor (T) stages, CTV-U and CTV-C motion in stage T1 was larger. A uniform CTV planning treatment volume margin of 15 mm failed to encompass the CTV-U and CTV-C in 11.1% and 2.2% of all fractions, respectively. The mean volume change of CTV-U and CTV-C were 150% and 51%, respectively, compared with the planning CTV. CONCLUSIONS: Movements of the uterine corpus are larger than those of the cervix. The likelihood of missing the CTV is significantly increased due to inter-fractional motion when utilizing traditional planning margins. Early T stage may require larger margins. Personal radiotherapy margining is needed to improve treatment accuracy.


Assuntos
Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Neoplasias do Colo do Útero/patologia , Planejamento da Radioterapia Assistida por Computador/métodos , Movimento (Física) , Pelve/patologia , Tomografia Computadorizada de Feixe Cônico/métodos , Radioterapia Guiada por Imagem/métodos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica
9.
Radiat Oncol ; 19(1): 49, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627747

RESUMO

OBJECTIVE: This study evaluates various craniospinal irradiation (CSI) techniques used in Turkish centers to understand their advantages, disadvantages and overall effectiveness, with a focus on enhancing dose distribution. METHODS: Anonymized CT scans of adult and pediatric patients, alongside target volumes and organ-at-risk (OAR) structures, were shared with 25 local radiotherapy centers. They were tasked to develop optimal treatment plans delivering 36 Gy in 20 fractions with 95% PTV coverage, while minimizing OAR exposure. The same CT data was sent to a US proton therapy center for comparison. Various planning systems and treatment techniques (3D conformal RT, IMRT, VMAT, tomotherapy) were utilized. Elekta Proknow software was used to analyze parameters, assess dose distributions, mean doses, conformity index (CI), and homogeneity index (HI) for both target volumes and OARs. Comparisons were made against proton therapy. RESULTS: All techniques consistently achieved excellent PTV coverage (V95 > 98%) for both adult and pediatric patients. Tomotherapy closely approached ideal Dmean doses for all PTVs, while 3D-CRT had higher Dmean for PTV_brain. Tomotherapy excelled in CI and HI for PTVs. IMRT resulted in lower pediatric heart, kidney, parotid, and eye doses, while 3D-CRT achieved the lowest adult lung doses. Tomotherapy approached proton therapy doses for adult kidneys and thyroid, while IMRT excelled for adult heart, kidney, parotid, esophagus, and eyes. CONCLUSION: Modern radiotherapy techniques offer improved target coverage and OAR protection. However, 3D techniques are continued to be used for CSI. Notably, proton therapy stands out as the most efficient approach, closely followed by Tomotherapy in terms of achieving superior target coverage and OAR protection.


Assuntos
Radiação Cranioespinal , Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Adulto , Humanos , Criança , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radiação Cranioespinal/métodos , Turquia , Radioterapia Conformacional/métodos , Radioterapia de Intensidade Modulada/métodos
10.
Technol Cancer Res Treat ; 23: 15330338241242654, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38584413

RESUMO

Purpose: Deep learning (DL) is widely used in dose prediction for radiation oncology, multiple DL techniques comparison is often lacking in the literature. To compare the performance of 4 state-of-the-art DL models in predicting the voxel-level dose distribution for cervical cancer volumetric modulated arc therapy (VMAT). Methods and Materials: A total of 261 patients' plans for cervical cancer were retrieved in this retrospective study. A three-channel feature map, consisting of a planning target volume (PTV) mask, organs at risk (OARs) mask, and CT image was fed into the three-dimensional (3D) U-Net and its 3 variants models. The data set was randomly divided into 80% as training-validation and 20% as testing set, respectively. The model performance was evaluated on the 52 testing patients by comparing the generated dose distributions against the clinical approved ground truth (GT) using mean absolute error (MAE), dose map difference (GT-predicted), clinical dosimetric indices, and dice similarity coefficients (DSC). Results: The 3D U-Net and its 3 variants DL models exhibited promising performance with a maximum MAE within the PTV 0.83% ± 0.67% in the UNETR model. The maximum MAE among the OARs is the left femoral head, which reached 6.95% ± 6.55%. For the body, the maximum MAE was observed in UNETR, which is 1.19 ± 0.86%, and the minimum MAE was 0.94 ± 0.85% for 3D U-Net. The average error of the Dmean difference for different OARs is within 2.5 Gy. The average error of V40 difference for the bladder and rectum is about 5%. The mean DSC under different isodose volumes was above 90%. Conclusions: DL models can predict the voxel-level dose distribution accurately for cervical cancer VMAT treatment plans. All models demonstrated almost analogous performance for voxel-wise dose prediction maps. Considering all voxels within the body, 3D U-Net showed the best performance. The state-of-the-art DL models are of great significance for further clinical applications of cervical cancer VMAT.


Assuntos
Aprendizado Profundo , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Dosagem Radioterapêutica , Neoplasias do Colo do Útero/diagnóstico por imagem , Neoplasias do Colo do Útero/radioterapia , Estudos Retrospectivos , Órgãos em Risco
11.
Radiat Oncol ; 19(1): 46, 2024 Apr 09.
Artigo em Inglês | MEDLINE | ID: mdl-38594678

RESUMO

OBJECTIVE: To evaluate effects of bone marrow sparing (BMS) radiotherapy on decreasing the incidence of acute hematologic toxicity (HT) for locoregionally advanced cervical cancer (LACC) patients treated by pelvic irradiation. MATERIALS AND METHODS: LACC patients were recruited prospectively from May 2021 to May 2022 at a single center and were evenly randomized into the BMS group and the control group. All patients received pelvic irradiation with concurrent cisplatin (40 mg/m2 weekly), followed by brachytherapy and BM V40 < 25% in the BMS group was additionally prescribed. Acute HT was assessed weekly. Binary logistic regression model and receiver operating characteristic (ROC) curve were used for predictive value analysis. The trial was registered with Chinese clinical trial registry (ChiCTR2200066485). RESULTS: A total of 242 patients were included in the analysis. Baseline demographic, disease and treatment characteristics were balanced between the two groups. In the intention-to-treat population, BMS was associated with a lower incidence of grade ≥ 2 and grade ≥ 3 acute HT, leukopenia and neutropenia s(72.70% v 90.90%, P < 0.001*; 16.50% vs. 65.30%, P < 0.001*; 66.10% vs. 85.10%, P = 0.001*; 13.20% vs. 54.50%, P < 0.001*; 37.20% vs. 66.10%, P < 0.001*; 10.70% vs. 43.80%, P < 0.001*). BMS also resulted in decreased dose delivered to the organs at risk (OARs) including rectum, bladder and left and right femoral head. Univariate and multivariate analyses showed that BM V40 was an independent risk factor for grade ≥ 3 acute HT (odds ratio [OR] = 2.734, 95% confidence interval [CI] = 1.959-3.815, P < 0.001*). Cutoff value was 25.036% and area under the curve (AUC) was 0.786. The nomogram was constructed, which was rigorously evaluated and internally cross-validated, showing good predictive performance. CONCLUSIONS: Receiving BMS pelvic irradiation could reduce the incidence of acute HT in LACC patients, and BM V40 < 25% may be a significant factor in reducing the risks of acute HT.


Assuntos
Leucopenia , Lesões por Radiação , Radioterapia de Intensidade Modulada , Neoplasias do Colo do Útero , Feminino , Humanos , Medula Óssea/efeitos da radiação , Neoplasias do Colo do Útero/radioterapia , Estudos Prospectivos , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Cisplatino , Leucopenia/etiologia , Quimiorradioterapia/efeitos adversos , Lesões por Radiação/etiologia
12.
Technol Cancer Res Treat ; 23: 15330338241241898, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38557213

RESUMO

Introduction: In this study, we sought to develop a thermoplastic patient-specific helmet bolus that could deliver a uniform therapeutic dose to the target and minimize the dose to the normal brain during whole-scalp treatment with a humanoid head phantom. Methods: The bolus material was a commercial thermoplastic used for patient immobilization, and the holes in the netting were filled with melted paraffin. We compared volumetric-modulated arc therapy treatment plans with and without the bolus for quantitative dose distribution analysis. We analyzed the dose distribution in the region of interest to compare dose differences between target and normal organs. For quantitative analysis of treatment dose, OSLD chips were attached at the vertex (VX), posterior occipital (PO), right (RT), and left temporal (LT) locations. Results: The average dose in the clinical target volume was 6553.8 cGy (99.3%) with bolus and 5874 cGy (89%) without bolus, differing by more than 10% from the prescribed dose (6600 cGy) to the scalp target. For the normal brain, it was 3747.8 cGy (56.8%) with bolus and 5484.6 cGy (83.1%) without bolus. These results show that while the dose to the treatment target decreased, the average dose to the normal brain, which is mostly inside the treatment target, increased by more than 25%. With the bolus, the OSLD measured dose was 102.5 ± 1.2% for VX and 101.5 ± 1.9%, 95.9 ± 1.9%, and 81.8 ± 2.1% for PO, RT, and LT, respectively. In addition, the average dose in the treatment plan was 102%, 101%, 93.6%, and 80.7% for VX, PO, RT, and LT. When no bolus was administered, 59.6 ± 2.4%, 112.6 ± 1.8%, 47.1 ± 1.6%, and 53.1 ± 2.3% were assessed as OSLD doses for VX, PO, RT, and LT, respectively. Conclusion: This study proposed a method to fabricate patient-specific boluses that are highly reproducible, accessible, and easy to fabricate for radiotherapy to the entire scalp and can effectively spare normal tissue while delivering sufficient surface dose.


Assuntos
Compostos Organotiofosforados , Radioterapia de Intensidade Modulada , Humanos , Radioterapia de Intensidade Modulada/métodos , Couro Cabeludo , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Estudos de Viabilidade , Dispositivos de Proteção da Cabeça , Órgãos em Risco/efeitos da radiação
13.
Sci Rep ; 14(1): 9148, 2024 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-38644367

RESUMO

Cryotherapy is an ablative therapy that can be used to treat localized prostate cancer. In case of recurrence, treatment options are not well-defined, and their outcomes are unknown. We therefore collected all patients treated with radiotherapy after cryotherapy for prostate cancer recurrence in Nantes (France) between 2012 and 2019. We identified ten patients. After a median follow-up of 5 years, two patients presented late grade 3 toxicities; one patient presented a grade 3 rectal hemorrhage, and one had a grade 3 hematuria. Two patients relapsed at 61 and 62 months, and three patients died of other causes. Radiotherapy to treat local prostate cancer recurrence after cryotherapy seems feasible and effective in local control. These results do not allow us to recommend this technique in current practice but are encouraging for the conduct of prospective trials.


Assuntos
Crioterapia , Recidiva Local de Neoplasia , Neoplasias da Próstata , Radioterapia de Intensidade Modulada , Terapia de Salvação , Humanos , Masculino , Neoplasias da Próstata/radioterapia , Idoso , Terapia de Salvação/métodos , Crioterapia/métodos , Radioterapia de Intensidade Modulada/métodos , Radioterapia de Intensidade Modulada/efeitos adversos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/radioterapia , Idoso de 80 Anos ou mais , Falha de Tratamento
14.
Cancer Med ; 13(8): e7191, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38659395

RESUMO

BACKGROUND: Patients with nasopharyngeal carcinoma (NPC) undergoing radiotherapy experience significant fatigue, which is frequently underestimated due to the lack of objective indicators for its evaluation. This study aimed to explore the longitudinal association between fatigue and nutrition status 1 week in advance. METHODS: From January 2021 to June 2022, a total of 105 NPC patients who received intensity-modulated radiation therapy were enrolled in the observational longitudinal study. The significant outcomes, including the Piper Fatigue Scale-12 (PFS-12), the Scored Patient-Generated Subjective Global Assessment (PG-SGA), four body composition indices, and the Hospital Anxiety and Depression Scale (HADS), were assessed weekly from pre-treatment until the completion of radiotherapy (T0-T7) to explore their relationship. RESULTS: The trajectories of PFS-12 and all dimensions for 105 participants reached a peak during the fifth week. Sensory fatigue consistently received the highest scores (T0 = 1.60 ± 2.20, T5 = 6.15 ± 1.57), whereas behavior fatigue exhibited the fastest increase over time (T0 = 1.11 ± 1.86, T5 = 5.47 ± 1.70). Higher PG-SGA scores were found to be weakly explainable for aggravating fatigue (ß = 0.02 ~ 0.04). Unlike generalized additive mixed models, marginal structural models (MSM) produced larger effect values (ß = 0.12 ~ 0.21). Additionally, body composition indices showed weakly negative relationships with fatigue in MSMs one week in advance. CONCLUSIONS: The PG-SGA may be a more accurate predictor of future-week fatigue than individual body composition indicators, particularly when HADS is controlled for as a time-dependent confounder.


Assuntos
Fadiga , Neoplasias Nasofaríngeas , Estado Nutricional , Radioterapia de Intensidade Modulada , Humanos , Fadiga/etiologia , Masculino , Feminino , Neoplasias Nasofaríngeas/radioterapia , Pessoa de Meia-Idade , Estudos Longitudinais , Radioterapia de Intensidade Modulada/efeitos adversos , Radioterapia de Intensidade Modulada/métodos , Adulto , Carcinoma Nasofaríngeo/radioterapia , Idoso , Composição Corporal
15.
Sci Rep ; 14(1): 9283, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38654028

RESUMO

We compared survival outcomes of high-dose concomitant boost radiotherapy (HDCBRT) and conventional dose radiotherapy (CRT) for newly diagnosed glioblastoma (GB). Patients treated with intensity-modulated radiation therapy for newly diagnosed GB were included. In HDCBRT, specific targets received 69, 60, and 51 Gy in 30 fractions, while 60 Gy in 30 fractions was administered with a standard radiotherapy method in CRT. Overall survival (OS) and progression-free survival (PFS) were compared using the Log-rank test, followed by multivariate Cox analysis. The inverse probability of treatment weighting (IPTW) method was also applied to each analysis. Among 102 eligible patients, 45 received HDCBRT and 57 received CRT. With a median follow-up of 16 months, the median survival times of OS and PFS were 21 and 9 months, respectively. No significant differences were observed in OS or PFS in the Kaplan-Meier analyses. In the multivariate analysis, HDCBRT correlated with improved OS (hazard ratio, 0.49; 95% confidence interval, 0.27-0.90; P = 0.021), and this result remained consistent after IPTW adjustments (P = 0.028). Conversely, dose suppression due to the proximity of normal tissues and IMRT field correlated with worse OS and PFS (P = 0.008 and 0.049, respectively). A prospective study with a stricter protocol is warranted to validate the efficacy of HDCBRT for GB.


Assuntos
Neoplasias Encefálicas , Glioblastoma , Radioterapia de Intensidade Modulada , Humanos , Glioblastoma/radioterapia , Glioblastoma/mortalidade , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Radioterapia de Intensidade Modulada/métodos , Adulto , Neoplasias Encefálicas/radioterapia , Neoplasias Encefálicas/mortalidade , Dosagem Radioterapêutica , Estimativa de Kaplan-Meier , Intervalo Livre de Progressão , Resultado do Tratamento
16.
Radiat Oncol ; 19(1): 39, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509540

RESUMO

BACKGROUND: At present, the implementation of intensity-modulated radiation therapy (IMRT) treatment planning for geometrically complex nasopharyngeal carcinoma (NPC) through manual trial-and-error fashion presents challenges to the improvement of planning efficiency and the obtaining of high-consistency plan quality. This paper aims to propose an automatic IMRT plan generation method through fluence prediction and further plan fine-tuning for patients with NPC and evaluates the planning efficiency and plan quality. METHODS: A total of 38 patients with NPC treated with nine-beam IMRT were enrolled in this study and automatically re-planned with the proposed method. A trained deep learning model was employed to generate static field fluence maps for each patient with 3D computed tomography images and structure contours as input. Automatic IMRT treatment planning was achieved by using its generated dose with slight tightening for further plan fine-tuning. Lastly, the plan quality was compared between automatic plans and clinical plans. RESULTS: The average time for automatic plan generation was less than 4 min, including fluence maps prediction with a python script and automated plan tuning with a C# script. Compared with clinical plans, automatic plans showed better conformity and homogeneity for planning target volumes (PTVs) except for the conformity of PTV-1. Meanwhile, the dosimetric metrics for most organs at risk (OARs) were ameliorated in the automatic plan, especially Dmax of the brainstem and spinal cord, and Dmean of the left and right parotid glands significantly decreased (P < 0.05). CONCLUSION: We have successfully implemented an automatic IMRT plan generation method for patients with NPC. This method shows high planning efficiency and comparable or superior plan quality than clinical plans. The qualitative results before and after the plan fine-tuning indicates that further optimization using dose objectives generated by predicted fluence maps is crucial to obtain high-quality automatic plans.


Assuntos
Neoplasias Nasofaríngeas , Radioterapia de Intensidade Modulada , Humanos , Carcinoma Nasofaríngeo/radioterapia , Radioterapia de Intensidade Modulada/métodos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco , Neoplasias Nasofaríngeas/radioterapia
17.
BMC Cancer ; 24(1): 374, 2024 Mar 25.
Artigo em Inglês | MEDLINE | ID: mdl-38528456

RESUMO

BACKGROUND: Chemo-radiotherapy with curative intent for anal cancer has high complete remission rates, but acute treatment-related gastrointestinal (GI) toxicity is significant. Toxicity occurs due to irradiation of surrounding normal tissue. Current radiotherapy requires the addition of large planning margins to the radiation field to ensure target coverage regardless of the considerable organ motion in the pelvic region. This increases the irradiated volume and radiation dose to the surrounding normal tissue and thereby toxicity. Online adaptive radiotherapy uses artificial intelligence to adjust the treatment to the anatomy of the day. This allows for the reduction of planning margins, minimizing the irradiated volume and thereby radiation to the surrounding normal tissue.This study examines if cone beam computed tomography (CBCT)-guided oART with daily automated treatment re-planning can reduce acute gastrointestinal toxicity in patients with anal cancer. METHODS/DESIGN: The study is a prospective, single-arm, phase II trial conducted at Copenhagen University Hospital, Herlev and Gentofte, Denmark. 205 patients with local only or locally advanced anal cancer, referred for radiotherapy with or without chemotherapy with curative intent, are planned for inclusion. Toxicity and quality of life are reported with Common Terminology Criteria of Adverse Events and patient-reported outcome questionnaires, before, during, and after treatment. The primary endpoint is a reduction in the incidence of acute treatment-related grade ≥ 2 diarrhea from 36 to 25% after daily online adaptive radiotherapy compared to standard radiotherapy. Secondary endpoints include all acute and late toxicity, overall survival, and reduction in treatment interruptions. RESULTS: Accrual began in January 2022 and is expected to finish in January 2026. Primary endpoint results are expected to be available in April 2026. DISCUSSION: This is the first study utilizing online adaptive radiotherapy to treat anal cancer. We hope to determine whether there is a clinical benefit for the patients, with significant reductions in acute GI toxicity without compromising treatment efficacy. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05438836. Danish Ethical Committee: H-21028093.


Assuntos
Neoplasias do Ânus , Radioterapia Guiada por Imagem , Radioterapia de Intensidade Modulada , Humanos , Qualidade de Vida , Estudos Prospectivos , Inteligência Artificial , Neoplasias do Ânus/radioterapia , Neoplasias do Ânus/etiologia , Resultado do Tratamento , Planejamento da Radioterapia Assistida por Computador/métodos , Diarreia/etiologia , Radioterapia Guiada por Imagem/efeitos adversos , Radioterapia Guiada por Imagem/métodos , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Ensaios Clínicos Fase II como Assunto
18.
Sci Rep ; 14(1): 7134, 2024 03 26.
Artigo em Inglês | MEDLINE | ID: mdl-38532018

RESUMO

We aimed to investigate the deliverability of dynamic conformal arc therapy (DCAT) by gantry wobble owing to the intrinsic inter-segment break of the Elekta linear accelerator (LINAC) and its adverse influence on the dose to the patient. The deliverability of DCAT was evaluated according to the plan parameters, which affect the gantry rotation speed and resultant positional inaccuracies; the deliverability according to the number of control points and dose rates was investigated by using treatment machine log files and dosimetry devices, respectively. A non-negligible degradation in DCAT deliverability due to gantry wobble was observed in both the treatment machine log files and dosimetry devices. The resulting dose-delivery error occurred below a certain number of control points or above a certain dose rate. Dose simulations in the patient domain showed a similar impact on deteriorated deliverability. For targets located primarily in the isocenter, the dose differences were negligible, whereas for organs at risk located mainly off-isocenter, the dose differences were significant up to - 8.77%. To ensure safe and accurate radiotherapy, optimal plan parameters should be selected, and gantry angle-specific validations should be conducted before treatment.


Assuntos
Radioterapia Conformacional , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Radioterapia Conformacional/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Aceleradores de Partículas , Radiometria/métodos , Radioterapia de Intensidade Modulada/métodos
19.
Ugeskr Laeger ; 186(12)2024 03 18.
Artigo em Dinamarquês | MEDLINE | ID: mdl-38533873

RESUMO

In early breast cancer, adjuvant moderately hypofractionated regimens are recommended for both whole breast, partial breast and locoregional irradiation which abbreviates the overall treatment time, as argued in this review. Gating is recommended as well as the use of a simultaneous integrated boost when indicated. A tangential field set-up is standard, however, for challenging cases volumetric modulated arc therapy techniques, or referral for proton therapy, may be considered. In the metastatic setting, stereotactic radiotherapy is a promising treatment option for oligometastatic disease.


Assuntos
Neoplasias da Mama , Feminino , Humanos , Neoplasias da Mama/radioterapia , Radioterapia de Intensidade Modulada/métodos
20.
Cancer Radiother ; 28(2): 159-163, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38548531

RESUMO

PURPOSE: Stereotactic body radiation therapy has been used for prostate cancer. However, the bulk of published studies on stereotactic body radiation therapy for prostate cancer has involved the irradiation of the prostate alone, without irradiation of the pelvic lymph nodes. We report our preliminary experience with this approach. MATERIAL AND METHODS: The files of patients with biopsy-proven prostate cancer treated with stereotactic body radiation therapy in our institution were reviewed. Stereotactic body radiation was delivered with intensity modulated-volumetric arctherapy with daily image-guidance. The prostate planning target volume included the prostate plus a margin of 5mm in all directions. The pelvic planning target volume included pelvic nodes plus an expansion of 6 to 7mm in all directions. The prostate planning target volume received a total dose of 36.25Gy delivered in five fractions on alternate days. The nodal planning target volume received a dose of 25Gy in the same five fractions. Patients were followed during treatment, after 1, and 3 months and every 6 months thereafter. Gastrointestinal and genitourinary toxicity was prospectively graded according to Common Terminology Criteria for Adverse Events. RESULTS: Among the 188 patients, 80 received stereotactic body radiation to the prostate and the pelvic nodes, while 108 received stereotactic body radiation to the prostate target only. Grade 2 acute gastrointestinal toxicity was 4% in both groups, and grade 2 acute genitourinary toxicity was 27% and 20% (P=0.9) for prostate only versus prostate and pelvis respectively. There was no grade 3 or higher acute gastrointestinal or genitourinary toxicity. CONCLUSION: Stereotactic body radiation therapy in five fractions including the prostate and pelvic nodes, in patients with high-risk prostate cancer, has been feasible and safe in terms of acute toxicity.


Assuntos
Neoplasias da Próstata , Radiocirurgia , Radioterapia de Intensidade Modulada , Masculino , Humanos , Próstata/patologia , Neoplasias da Próstata/patologia , Pelve , Radiocirurgia/efeitos adversos , Radioterapia de Intensidade Modulada/efeitos adversos , Linfonodos/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...